Adapt Plant · Site-scale product line

Adapt, engineered for larger skid-based process duties.

Adapt Plant applies the same modular process and control philosophy as compact Adapt, using larger-volume equipment, packaged process skids and project-engineered site integration. It is a separate product line—not a larger container or a fifth compact model.

Product definition

A plant assembled around the case—not a fixed machine.

The functional boundaries stay explicit. Capacity, feed chemistry, equipment duty, materials, skid count, civil works and physical layout are established through the signed project basis.

The objective is not maximum performance on paper. It is a stable, repeatable and controlled environment in which a validated process can behave consistently. Feed acceptance, preparation, reaction, separation, holding and recovery remain named functions.

Plant scaling is not proportional enlargement. Structural loads, lifting, transport, site assembly, access, containment, foundations and utilities are independently engineered for the selected installation.

Project-definedRM-1 working volumeSelected from the approved case basis
TBD at G0/G1throughput and train dutyNo inherited headline capacity
One or moreapproved identical trainsExact count is project-specific
P0 HOLDcurrent architecture statusNo procurement or performance release

Frozen functional topology

No bypasses hidden in the diagram.

The sequence below is the current Plant reference route. ERM-P raffinate returns only to HM-1; there is no direct AFCM-P-to-RM-1 bypass.

Compact Adapt vs Plant

Shared logic does not mean shared hardware.

This comparison makes the scale boundary visible without implying that compact-model specifications carry over to Plant.

AttributeAdapt 20C / 20X / 40S / 40PAdapt Plant
IdentityFour compact Reaction Module configurationsSeparate site-scale Adapt product line
Reaction equipmentCompact AE630-based arrangementsLarger-volume project-selected equipment; working volume remains HOLD until G0/G1
Deployment20-ft and 40-ft transportable architecturesSkid-based, site-integrated equipment
Scaling methodSelect model / add verified compact capacityAdd verified trains; capacity-match every active function
Utility functionModel/configuration-specificUM-1 is an active process module matched to the selected case
Layout basisContainer configuration plus site interfacesProject-specific zoning, foundations, access, containment and civil works
AutomationLocal deterministic execution under shared governanceSame authority model: PLC executes, safety vetoes, Olerib supervises
ReadinessPublished basis*Project sizing data required

Functional-boundary responsibilities

Every named boundary remains in the reference sequence.

Project-specific equipment and technology inside each boundary remain case-selected. No boundary is omitted, reordered or bypassed without a controlled architecture change.

BoundaryOwnsDoes not own
AFCM-PFeed acceptance, classification and controlled conditioningUnqualified direct feed to reaction
UM-1Slurry preparation, buffering, utility distribution and transferMetal recovery
RM-1Kit-governed primary processingUpstream feed qualification
SM-1Explicit post-reaction phase separationFinal product release
HM-1Holding, balancing and controlled return interfaceUnverified recycle
ERM-PLocked recovery/finishing boundary and controlled raffinate returnOne universal recovery technology or product specification